Authorized Wholesale Dealer of a wide range of products which include metravi loop calibrator cal-400-3 mv ma, donnelly chute level transmitter controller m11 max and dms-100 ms-1000 dust monitor.

Metravi Loop Calibrator CAL-400-3 mV mA

Metravi Loop Calibrator CAL-400-3 mV mA
  • Metravi Loop Calibrator CAL-400-3 mV mA
  • Metravi Loop Calibrator CAL-400-3 mV mA
  • Metravi Loop Calibrator CAL-400-3 mV mA
  • Metravi Loop Calibrator CAL-400-3 mV mA
Get Best Quote
Approx. Price: Rs 6,500.00 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Display TypeDigital
Usage/ApplicationIndustrial
Model Name/NumberCAL-400-3
TypeLoop Calibrator
BrandMetravi
Accuracy+-0.25%

  • Portable  instrument for Calibrating process  devices and measuring Process signals
  • The Instrument Powers or measures a two wire Current loop 
  • Four function provide the quality and accuracy of Hand Held  Calibrator
  • Display  :  LCD display max display counts 1999
  • Current Source :  0 – 19.99mA / 0 – 24mA
  • Accuracy :  ±0.25%
  • DC mV Source :  -199.9mA to ±199.9mV
  • Accuracy :  ±0.25%
  • Current Measurement  :  0 – 19.99mA / 0 – 24mA
  • Accuracy :   ±0.25%
  • Power & Current Measurement of two wire loop :  0 – 19.99mA / 0 – 24mA
  • Accuracy :   ±0.25%
Request
Callback
Yes! I am Interested

Donnelly Chute Level Transmitter Controller M11 Max

Donnelly Chute Level Transmitter Controller M11 Max
  • Donnelly Chute Level Transmitter Controller M11 Max
  • Donnelly Chute Level Transmitter Controller M11 Max
  • Donnelly Chute Level Transmitter Controller M11 Max
Get Best Quote
Approx. Price: Rs 15,000.00 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Voltage240V AC
Operation TypeManual to Automatic Switch
Mounting TypePanel
Model Name/NumberM11
Power240VAC
Usage/ApplicationIndustrial

Product Description

Introduction

This is micro-processor based Donnelly Chute level Transmitter with isolated o/p (4-20 mA), 10nos digital optical o/p and 2 relay control .The instrument is field programmable and user friendly.

In this Instrument user can set sensor sensitivity, sensor level selection, sample delay time and relay set point etc. The user can set level 2-10 then instrument automatically tunes for o/p 4-20 mA and display 0-100%.

The instrument has five settable parameters like rL1,rL2,snt,trl,Lst. The Instrument reads input level in sequence 1 to 10 if misplaced any level then it will not show above levels.

 

Parameters
Snt: Sensor Sensitivity adjustment
Lst: Level Sensor selection (2-10)
Trl: sample Delay adjustment
RL1 and rL2 : Relay set point (0-100)

snt(sensitivity adjustment Parameter)

In this parameter user can set sensitivity of every (1-10 sensor) level sensor through key pad. The sensor value can be set in this parameter 93(Max.) to (185min.) sensitivity and it is normally set 100 value of every sensor.

If snt set 93 then i/p led direct on without input connection.

Lst(level selection parameter)

The user can be set input level 2-10 then instrument automatically tune for o/p 4-20 mA and display 0-100%

Trl = 20 set
rL1,rL2 : Relay set point value

Terminal Details
S1 to S10 : i/p for probe type level sensor
GND : Common terminal of probe sensor (Donnelly chute sensor)
L1 to L10 :o/p for isolated digital out put to plc
+24vdc : +v common (+24 vdc) for plc digital i/p
O/p 4-20 mA : mA output (isolated)
P : common terminal of Relay
N/O : Normaly open terminal of Relay
N/C : Normaly close terminal of relay
L : Phase of 220v AC @50/60Hz
N : Neutral
E : Earth


Configuration

1st press both PRG+ DN key for 5 seconds then display rL1 press ENT key

display last load value if change then Use up/dn key and press ENT key

display rL2 press ENT key display last load value if change then use up/dn key And press ENT key

display snt press ENT display 001(it means level 1 select to adjust sensitivity) press ENT

display last load value of sensor 1 sensitivity , if you want change value then use up/dn if value decrees (it means sensitivity higher side(93 max.) ) if value increase (it means sensitivity lower side(185 min.) if you want to store modified value then press and hold PRG key after press ENT key now release both key now modified value has been stored .

If you do not want to change in this parameter then use only ENT key, if press only ENT key it means by pass snt parameter, if press PRG key and ENT key it means modified value stored and display snt for next level sensor sensitivity calibration And same process apply for level 1 to level 10 after that, Next parameter Lst display press ENT key display last level select if change (2-10) then use up/dn key press ENT key display trL press ENT key display last value and set 20 and press ENT key and now exit configuration mode.

Wait for Run led on (Run led on it means ,system in run mode.)

Troubleshooting

1. Fault 01 : If Display Eror1
2. Fault 03 : if Display 100% value on fnd display
3. Fault 02 : if Display Eror2

Fault 01: if Display Eror1 message it means wrong level select, now re-select level in Lst
Parameter (2-10)

Fault 02: if system display Eror2 message it means stored data has be corrupted now switch off of power and press and hold up and ENT key now switch on of power and hold up to counting display 1 to 9 now release Both key.

Fault 03 : If 100% value On Fnd display and all input led(red colored) glow without input level connection.

Wisntraop Automal
Request
Callback
Yes! I am Interested

DMS-100 MS-1000 Dust Monitor

DMS-100 MS-1000 Dust Monitor
  • DMS-100 MS-1000 Dust Monitor
  • DMS-100 MS-1000 Dust Monitor
Get Best Quote
Approx. Price: Rs 1.68 Lakh / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Usage/ApplicationDust Monitor
Model Name/NumberDMS-100 MS-1000
Analog Output4-20mA
Supply Voltage24VDC
Measuring principleLaser backward scattering
Measuring range0-200mg/m3, 0-10g/m3 (customizable)

DMS-100/MS-1000 dust particle measuring device consists of the optical part, circuit and signal processing part, calibrator and air curtain protection part.

The laser beam (650nm) emitted by semiconductor laser enters the stack and produces scattering light by interaction with dust particles. The backscattered light of the DMS-100/MS-1000 dust particle measuring device enters the photosensitive detector through the convergence of the lens. The signal processing circuit converts the light signal into a standard signal in proportion to dust concentration and output, thus dust particle emission concentration of pollution source is obtained.
Request
Callback
Yes! I am Interested
X

Product Videos

Explore More Products

View All Products




Reach Us
WISHTROOP AUTOMATION (Co Founder)
Wishtroop Automation
A-31/155, Second Floor, Street No.6, Mata Mandir Marg, Maujpur
Shahdara, New Delhi - 110053, Delhi, India
Get Directions


Call Us


Send E-mail